Electrophoresis Equipment

New Brochure:
Instruments for Life Sciences Research!

Electrophoresis Systems &
Laboratory Equipment:

  • Vertical Electrophoresis
  • Horizontal Electrophoresis
  • Power Supplies
  • Spot Picker
  • Blotting Apparatus
  • Gel Documentation and Analysis
  • Centrifuges
  • Thermoshakers
  • 3D Shaker
  • Aspiration Systems

 

tab_HPE_s.jpg

HPE™ BlueHorizon

The HPE™ BlueHorizon™ is a flatbed system for horizontal electrophoresis using precast gels, self-cast gels and gel strips. Main applications are isoelectric focusing (IEF) including the run of IPG strips (like SERVA IPG BlueStrips) in 2D PAGE and SDS PAGE, but also the separation of nucleic acids in polyacrylamide gels.
The unit consists of a stable metal housing and an integrated drawer. The drawer holds the cooling plate with connectors for the external refrigeration system (e.g. the circulatory refrigerator bath HPE™ Cooling Unit, cat. no. HPE-CU1). The cooling plate is made from special ceramic material (maximum gel size 260 x 205 mm) for efficient cooling. It provides even heat dissipation, allowing to run gels at a temperature as low as 4 °C. This is particularly important when applying high voltage to thin isoelectric focusing (IEF) gels.
The electrode lid comes with one pair of platinum electrodes. Three fixed electrode positions allow the usage of a wide range of different sized gels. Optional, an electrode lid with a triple electrode arrangement for bi-directional gel run is available. The easy-to-clean housing allows placing the power supply on top of the unit saving valuable space on your bench.

  • High capacity cooling plate suitable for high voltage applications like IEF etc.
  • Fixed platinum electrode distances of 270 mm, 195 mm and 115 mm
  • For all kinds of film-backed flatbed gels, selfcast or precast
  • Samples are easy to load
  • Economical reagent usage (minimizing running buffer volume)
  • Smart design - made in Germany

HPE™ Tower System

The HPE™ Tower System allows electrophoretical separations in up to four horizontal gels at the same time. It is used for 1D and 2D electrophoresis gels, where multiple runs are an important demand. Structurally, the HPE™ Tower consists of four horizontal electrophoresis chambers, which are built as movable drawers into a metal housing.
The HPE™ Tower and the HPE™ gels have been developed together as a system, in order to achieve better results than can be obtained with conventional SDS polyacrylamide gel electrophoresis (PAGE) technology. The precast HPE™ gels, which are less than 1 mm thin and film-backed, are protected from light during the run. No glass plates are used. They are placed on aluminum oxide ceramic cooling plates, which ensures very efficient heat dissipation and therefore straight electrophoretic migration in each gel.
Content:
HPE™ Tower (HPE-T02), HPE™ Power Supply Package (HPE-PSP) and HPE™ Cooling Unit (HPE-CU1).

SERVA HPE™ ScreenPicker

 

The semi-manual SERVA HPE™ ScreenPicker alllows spot picking from fluorescent gels without visual post staining. The gel is placed on a horizontal flat screen which displays the scanned 2D image 1:1. Spots to pick are visualized one at a time by crosshair on the image. The plugs are disposed error-free into 96 well plates by using the picking list and the intgrated plate identifier control.
- Semi-manual spot picking from fluorescent gels
- 2D image displayed 1:1 on gel via flat screen
- Guided picking spot by spot with error-free plug disposal
Content:
Screen picker complete with PC, software and picker head

BlueMarine™ 100

Gel format 7 x 10 cm for quick analysis of up to 28 samples. Contains main unit and also: 1 removable UV transparent gel tray (7 x 10 cm), 2 gel casting gates, 1 comb (1.0 mm, 8 samples).

Operational Data

Maximum operating voltage:
Maximum operating current:
Approx. gel volume (5 mm gel):
Possible comb positions:
Maximum of loadable samples:
Electrode separation:
Recommended volts per cm:
300 Volt
200 mAmp
35 ml
2
28
18 cm
14 - 140

BlueMarine™ 200

Gel formats 15 x 15 cm or 15 x 20 cm for best resolution or high throughput analysis. Contains main unit and also: 1 removable UV transparent gel tray (15 x 20 cm), 1 removable UV transparent gel tray (15 x 15 cm), 2 gel casting gates, 2 combs (1.0 mm, 16 samples).

Maximum operating voltage:
Maximum operating current:
Approx. gel volume (5 mm gel):
Possible comb positions:
Maximum of loadable samples:
Electrode separation:
Recommended volts per cm:
500 V / 500 V
300 mA / 300 mA
115 ml / 150 ml
2 / 4
62 / 124
28.5 cm / 28.5 cm
20 - 200 / 20 - 200

BluePower™ 500x4 Power Supply

The allround instrument serving many applications, e.g., SDS PAGE, submarine electrophoresis and blotting. BluePower™ 500x4 features 500 V, 1000 mA and 200 W. The BP-500x4 power supply is particularly advised for operation of up to four vertical slab gel units run at higher voltage, also resulting in shorter running times and for blotting applications (tank blot, semi-dry blot). 4 x 2 outlets, programmable.

 

BluePower™ 3000x4 Power Supply

BluePower™ 3000x4 is designed for high voltage applications (isoelectric focusing, DNA sequencing) delivering 3000 V, 200 mA and 300 W. Other applications (SDS PAGE, submarine electrophoresis) can be performed as well. 4 x 2 outlets, programmable.

 

 

BlueVertical™ PRiME™ - the new mini slab gel system from SERVA

BV104_new_b.jpg

BlueVertical™ PRiME™ has been especially designed to run SERVAGel™ precast gels and other precast gels with an outer cassette dimension of 10 x 10 x 0.7 cm.
The fixture of the inner core unit has been completely re-engineered  to ensure the precise fit of the gel cassette(s). The BlueVertical™ is the perfect electrophoresis mini tank system to run precast gels in SDS PAGE, native PAGE, IEF or nucleic acid PAGE applications. A unique innovative clamp system keeps the gel cassettes in their correct place at the inner core running module, leak-free and ready to start within seconds. Built-in convenient operation features result in improved daily work.
Developed, produced and assembled in Germany – another top quality product from SERVA.

  • Superb results
  • Top resolution
  • Easy and safe to handle
  • Unique, leak-free clamp system
  • Ergonomic, compact design
  • For SERVAGel™ precast gels

BlueFlash™ Medium

Semi-dry blotting is faster than tank blotting. It requires less material and generates less heat. This has to do with the large volume of electrically conductive buffer used in tank blotting. Attempts to achieve high electric field strengths for rapid blotting lead to very high current demands and consequently large heat loads. These are not usually a factor in semi-dry blotting as the closely spaced electrodes separated by less conductive saturated filter papers permit rapid electrophoresis without the very high current. Both, discontinuous and continuous buffer systems can be applied. Discontinuous buffer systems are particularly recommended because transfer is very homogeneous for a wide range of molecular weights, even larger proteins up to 200 kDa can be transferred with an efficiency of > 80%. The BlueFlash™ Semi-Dry Blotters are equipped with long-lasting electrodes made from synthetic carbon. They are resistant to corrosion (pH 3 - 9, SDS) and built for homogeneous, fast and efficient transfer of nucleic acids and proteins. The spring-mounted anode can be adapted to thicker gels (up to 5 mm) and gel stacks. The acrylic housing is resistant to 10 % ethanol and easy to clean. Safety lid, including design to prevent short-circuit (no gel). Little bench space required. Flexible Format and Application: Choose the right format for your application. SERVA offers semi-dry blotter units with various blotting areas ranging from small-sized BF-S and BF-M for mini gels up to large format BF-XXL to fit 2D gels. The sizes available suit all gel formats. They are suitable for blotting of large format gels (e.g. 2D) or simultaneous transfer of a series of mini gels. Usually, stacks of 2 gels can be blotted

SERVA BlueThermo H/HC

BT-H-s.jpg

Temperature control on your bench!
The SERVA BlueThermo H and HC shakers are precise heating (H) and heating & cooling (HC) thermoshakers.

SERVA BlueThermo H/HC

SERVA BlueShake 3D

BS-3D-s.jpg

The SERVA BlueShake 3D works with a rotational 3D motion and is flexible applicable in various incubation and preparation techniques (e. g. staining/destaining procedures).

SERVA BlueShaker 3D

 

SERVA BlueCell vario

 

 

Automatic cell culture aspiration system with autoclavable 4 l - bottle. With the handle, the aspiration speed and suction start / stop is regulated. Extendable for up to four users by connecting more bottles and handles. Space saving setting with bottle on top. The membrane vacuum pump is mounted in a metal-solid body. The pump is noise reduced, produces a vacuum down to 100 mbar and aspiration speed of 17 l / min. The 4 l polypropylene bottle with fast-lock clutches ensures an easy removal for cleaning. The safety filter prevents leaking of liquids.

  • Dimensions (W x D x H): 170 x 220 x 155 mm

 

 

 

 

 

 


  • stain G.jpg
    SERVA DNA Stain G is a safer alternative to traditional ethidium bromide stain for detecting nucleic acid in agarose gels. It is at least as sensitive as ethidium bromide and can b...

  • IEF.jpg
    SERVALYT™ Carrier Ampholytes SERVALYT™ Carrier Ampholytes are low molecular weight molecules of zwitterionic character. They are a mixture of synthetically derived species of avera...

  • SDS.jpg
    SERVAGel Precast Vertical Gels SERVAGel™ precast vertical gels for mini slab gel electrophoresis are ready-to-use, prepared from acrylamide-bis and cast into unbreakable plastic ca...

  • 2D.jpg
    IPG Strips for 1D / 2D GE SERVA IPG BlueStrips are dried gel strips with immobilized pH gradient used in high resolution 2D gel electrophoresis of proteins. The strips have to be r...

  • blot.jpg
    Detection Reagents Before membrane bound antigens can be detected, unspecific binding sites for antibodies on the transfer membrane have to be blocked. For many applications skim ...

  • BM100.jpg
    Agarose Media The electrophoretic behavior in gels of DNA and RNA is effected by their size and shape. Both RNA and DNA can exist as single and double stranded molecules and the s...

  • stain.jpg
    Staining Kits Depending on the required sensitivity protein gels are Coomassie®-, silver or fluorescence stained after electrophoresis.Besides SERVA DensiStain Blue G for rapi...


  • new_64300802.jpg
    DOWEX® Ion Exchange Resins DOWEX® resins are made of spherical particles. The benefit for the user is a highly efficient exchange process, due to optimal flow-through kinetics bec...
Visitors: 212,547